Guide by PLC Type

Pick the guide that matches your PLC or equipment model. 44 protocols plus Motor Sense are supported.

Which category should you start with?
  • Factory automation / production lines — Mitsubishi, Siemens, LS, AB, OMRON, Panasonic, FATEK, Beckhoff
  • General purpose / standards — OPC-UA, Modbus TCP/RTU, HTTP
  • Automotive fastening (screwdrivers) — Atlas Copco Open Protocol
  • Energy / utilities — DNP3, IEC 61850, M-Bus, HART-IP
  • Building / facilities — BACnet/IP, KNXnet/IP, DALI
  • Semiconductor fab — SECS/GEM
  • Robotics / AGV / motion — ROS 2, CANopen, IO-Link
  • Marine / shipboard — NMEA 0183
  • DCS / process — Emerson DeltaV (via OPC-UA)

If you're not sure which guide to read

General-purpose / standard protocols

Your equipment / environmentRecommended protocolGuide
Kepware / Matrikon / OPC-UA serverOPC-UAOPC-UA
General instruments / inverters / standard industrial devices (TCP)Modbus TCPModbus TCP
RS-485 / RS-232 serial instruments (via gateway)Modbus RTU(coming soon)
External IT / MES / ERP pushes valuesHTTPHTTP Push

Factory automation / general PLC lines

Your equipmentRecommended protocolGuide
MITSUBISHI — Q / iQ-R / iQ-F / FXMELSEC (MC Protocol)MELSEC
SIEMENS — S7-1200/1500/300/400S7 (TIA / Step7)Siemens S7
LS ELECTRIC (formerly LSIS) — XGI / XBC / XBMLS XGT FEnetLS ELECTRIC
Allen-Bradley / Rockwell — ControlLogix / CompactLogixEtherNet/IP CIPAB EtherNet/IP
Allen-Bradley legacy — PLC-5 / SLC-500 / MicroLogixAB-EtherNet(coming soon)
GE Fanuc — RX3i / RX7i / 90-30SRTP(coming soon)
OMRON — CJ / CS / NJ / NX (FINS)OMRON FINS(coming soon)
Panasonic / Matsushita — FP seriesMEWTOCOL(coming soon)
FATEK — FBs / FB-MCFATEK FBs(coming soon)
Beckhoff TwinCAT — CX / IPCADS / AMS(coming soon)

Automotive / fastening / torque management

Your equipmentRecommended protocolGuide
Atlas Copco / Bosch Rexroth / automated screwdrivers (fastening result collection)Open Protocol(coming soon)

Energy / utilities / metering

Your equipmentRecommended protocolGuide
Substation IEDs / protective relays / power SCADAIEC 61850 (MMS)(coming soon)
Transmission & distribution / RTUs / power utility SCADADNP3 (IEEE 1815)(coming soon)
HART 4-20mA transmitters (refining/chemicals) — HART-IP gatewayHART-IP(coming soon)
Gas / water / heat meters (EN 13757)M-Bus(coming soon)

Building / lighting / HVAC

Your equipmentRecommended protocolGuide
Building automation — HVAC / FCU / AHU controllersBACnet/IP(coming soon)
Lighting automation (KNX-based buildings)KNXnet/IP(coming soon)
Lighting dimming / lighting automation (DALI master required)DALIDALI Guide

Motion / robotics / sensors

Your equipmentRecommended protocolGuide
Profinet-based PLCs / IO devicesProfinet(coming soon)
CAN-based motion / drives / AGVsCANopen(coming soon)
IO-Link sensors (via sensor master)IO-LinkIO-Link Guide
ROS 2-based robots / autonomous AGVsROS 2ROS 2 Registration

Semiconductor fab

Your equipmentRecommended protocolGuide
Semiconductor / display fab equipment (E5 / E37)SECS/GEM (HSMS)(coming soon)

Marine / shipboard / navigation

Your equipmentRecommended protocolGuide
Ship navigation / GPS / AIS / anemometers (read-only)NMEA 0183(coming soon)

DCS / process control

Your equipmentRecommended protocolGuide
Emerson DeltaV DCS (via OPC-UA Connect recommended)DeltaVDeltaV Guide

KOPENS integration

EnvironmentRecommended guide
KOPENS Motor Sense (motor vibration / diagnostics)Motor Sense

Input fields common to all PLCs

These fields are asked for regardless of PLC type.

FieldMeaning
Connection IDUnique code identifying this PLC within the gateway
Connection nameName shown on screen
IP addressNetwork address of the PLC
PortCommunication port of the PLC (default varies by PLC type)
Collection interval (ms)How often values are read, in ms (typically 1000 = 1 second)
Auto startWhether collection starts automatically when the gateway reboots
Serial / non-IP protocols

Serial and fieldbus protocols such as Modbus RTU, M-Bus, NMEA 0183, DALI, IO-Link, and CANopen require a separate gateway / master / converter. In these cases, enter the converter's IP for the IP address and port (e.g., USR-TCP232, MOXA NPort).


Comparison table (all 25 protocols)

GuideCategoryDefault portAuthenticationSpecial optionsWriteStatus
OPC-UAGeneral4840 / 49320Optional (User/X.509)discovery modeYesReleased
Modbus TCPGeneral502Nonerequest-timeout, unit-idYesReleased
Modbus RTUGeneral (serial)(serial converter IP:port)Nonebaud / parity / unit-idYesStable
HTTP PushGeneral(n/a)API keypushed from outsideYesReleased
MELSECFactory automation5000 (Q/L) / 1500 (iQ-R)Nonecontroller-typeYesReleased
Siemens S7Factory automation102Nonerack / slotYesReleased
LS ELECTRICFactory automation2004 (XGT)Noneuse-checksumYes (Bit/Byte/Word/DWord/Float/Double)Released
AB EtherNet/IPFactory automation44818Nonebackplane / slotYes (varies by firmware)Released
AB-EtherNet (PLC-5/SLC-500)Factory automation2222 (CSP)NonestationNo (read-only)Stable
GE SRTPFactory automation18245Nonecontroller-typeYesReleased
OMRON FINSFactory automation9600Nonenetwork/node/unitYesReleased
Panasonic MEWTOCOLFactory automation9094Nonestation-noYesReleased
FATEK FBsFactory automation500Nonestation-noYesReleased
Beckhoff ADSFactory automation48898 (TCP) / 851 (target AMS port)Nonetarget-netid, target-portYesReleased
Atlas Copco Open ProtocolAutomotive / fastening4545NoneMID filterNo (fastening results read-only)Released
IEC 61850Energy102 (MMS/COTP)NoneLD/LN, FCNo (polling read-only)Stable
DNP3Energy20000Nonemaster/outstation addrYesReleased
HART-IPEnergy (refining/chemicals)5094Nonecommand setPartial (4-20mA)Released
M-BusEnergy (metering)(serial converter)Noneprimary addressNo (read-only)Released
BACnet/IPBuilding47808Nonedevice-id, object-idYesStable
KNXnet/IPBuilding3671Nonegroup addressYesStable
DALIBuilding (lighting)(DALI master IP)Noneshort-addressYes (dimming/color temperature)HW-dependent stub
ProfinetMotion / IO34962-34964Nonedevice nameYesStable
CANopenMotion / drives(CAN gateway)Nonenode-id, PDOYesStable
IO-LinkSensors(master IP)Noneport-id, ISDUYesHW-dependent stub
ROS 2Roboticsrosbridge (WebSocket 9090)ws/wsspath, tlsNone (read-only)rosbridge implementation
SECS/GEMSemiconductor fab5000 (HSMS)NoneT3-T8 timerYes (S2F41 host command)Stable
NMEA 0183Marine / navigation10110 (TCP)Nonesentence filterNo (read-only)Released
DeltaVDCS4840 (OPC-UA)User/X.509via OPC Connect recommendedYesGuide (uses OPC-UA)
Motor SenseKOPENS integration4840 (OPC-UA)Optionalautomatic asset discoveryYesReleased
What write support means

"Write" indicates whether an external system (REST /api/v1/tag/{tagId}/value, the Node-RED tag value write node, etc.) can change PLC values. In production, systems are generally operated read-only for safety, with write permission granted only to the specific tags that need to be changed.

EIP / SECS / IEC 61850 compatibility
  • EIP: Depending on PLC firmware/patch level, writes of certain data types may be rejected.
  • SECS/GEM, IEC 61850: Core messages (S1F1/F3, S2F41, MMS Read) are fully supported, but GEM/IED options vary widely by equipment model, so advance verification is recommended.
  • Always verify on a test slot or a field-approved test tag before applying to live equipment.
Broad industrial protocol support

Modbus RTU / AB-EtherNet (PLC-5) / BACnet/IP / KNXnet/IP / CANopen / Profinet run on a common integration engine aimed at broad device compatibility. Their options are simple, but they operate reliably across many verified devices.

HW-dependent stubs

DALI / IO-Link / DeltaV require a separate master / gateway / DCS system. (ROS 2 collects directly as long as rosbridge_server is running on the robot.) PlantPulse Edge is responsible only for communicating with that master.